跳至主要内容

Method of Reducing Silicon Burning Probability in Medium Frequency Furnace

Medium Frequency Furnace

Method of Reducing Silicon Burning Probability in Medium Frequency Furnace


The following describes the method of reducing the probability of silicon burning in the medium frequency furnace.

The thyristor is the heart of the medium frequency power supply of medium frequency furnace, its correct use is very important for the operation of equipment. It is normal to damage several thyristors occasionally during the use of medium frequency furnace. If silicon is often burned, it will cause alarm. The working current of the thyristor is several thousand a and the voltage is usually one or two thousand v. good protection of the main control board and good water-cooling conditions are necessary.

Overload characteristic of thyristor: the damage of thyristor is called breakdown. Under normal water-cooling conditions, the current overload capacity can reach more than 110%; without voltage overload capacity, that is to say, silicon is definitely damaged under overpressure. Considering the surge voltage, manufacturers often choose the silicon element according to 3-4 times the working voltage when manufacturing equipment. For example, when the rated working voltage of the intermediate frequency cabinet is 1750V, two silicon elements with voltage resistance of 2500V are selected to work in series, which is equivalent to 5000v.

Correct installation pressure of SCR: 150-200kg / cm2. When the equipment is delivered from the factory, it is generally installed by the hydraulic press. The maximum force of an ordinary wrench can't reach this value manually, so it's unnecessary to worry that silicon will be crushed during manual pressure mounting; if the pressure is loose, silicon will be burned due to poor heat dissipation.

Radiator structure of silicon controlled rectifier: water cooling cavity + multi copper pillar support. If the circulating water is too hard, it will scale inside the water chamber and cause poor heat dissipation; if the water chamber enters into leaves and other debris, it will also cause poor water flow.

induction furnace for sale


The factory test temperature of the thyristor is 100 ℃ (junction temperature). Generally, the circulating water temperature of the electric cabinet is kept below 45 ℃ to ensure its normal operation. The hand-held infrared thermometer is very useful. The thermometer at 350 ℃ costs only a few hundred yuan, which is not too expensive. It can be used to measure the temperature of thyristor and radiator of the working power supply, find out the abnormal points in time, and deal with the faults.

The surface of the radiator must match the dimension of the surface of the element to prevent the device from being damaged due to the bias and skew of the pressure. The surface of the radiator must be smooth and smooth. It is recommended that the surface roughness of the radiator is less than or equal to 1.6mm, and the flatness is less than or equal to 30mm. During installation, the component table and radiator table shall be kept clean and free of dirt such as oil stain.

During installation, keep the silicon element table and the radiator table completely parallel and concentric. During installation, it is required to apply pressure through the centerline of the element to make the pressure evenly distributed in the whole contact area. When the user installs by hand, it is recommended to use a torque wrench to alternately and evenly force all fastening nuts, and the pressure should meet the specified requirements.

When reusing the water-cooled radiator, special attention shall be paid to check whether the tabletop is smooth and flat, whether there is scale and blockage in the water chamber, especially whether the tabletop has sagged, if any, it shall be replaced.

Medium Frequency Furnace for sale


More News You May Interesting:

Melting Features of Medium Frequency Electric Furnace

Electric Arc Furnace VS Intermediate Frequency Furnace

Cause Analysis and Solution of Induction Coil Blocking in Medium Frequency Smelting Furnace

Why Intermediate Frequency Furnace cannot be Turned on Normally?

Energy Efficiency Control System of Submerged Arc Furnace

Furnace Transformer – Electric Arc Furnace

What is Induction Furnace?

How does a Blast Furnace Work?

Significance of Reheating Furnace Technology in Rolling Reheating Furnace

Why Use Coke for Blast Furnace Ironmaking does not Use Coal Directly?

How to Improve the Thermal Efficiency of the Reheating Furnaces?

What is the Reheating Furnace Temperature System?

Advantages of Walking Beam Reheating Furnace

Walking Beam Reheating Furnace

The Development Trends and Advantages of Electric Arc Furnaces

The Advantage of Induction Furnace ( Medium Frequency Furnace)

Induction Furnace for Sale

评论

此博客中的热门博文

Application Range of Medium Frequency Induction Furnace

  Application Range of Medium Frequency Induction Furnace (1) Intermediate frequency induction furnace is used for forging and rolling 1. Wheel forgings, ring forgings, shaft forgings, cylinder forgings, gear forgings, stainless steel forgings, and large flanges. 2. Hot heading of standard parts and fasteners, such as heating for tempering, forging, and extrusion of high tools. 4. Quenching and tempering of bar materials (2) Intermediate frequency induction furnaces are used for smelting   Including the smelting of steel, gold, silver, copper, and aluminum, especially in the foundry industry (3) Intermediate frequency induction furnace is used for heat treatment 1. Heat treatment of various hardware tools and hand tools. Such as pliers, wrenches, screwdrivers, hammers, axes, etc. 2. High-frequency hardened crank pins, sprockets, camshafts, valves, various rocker arms, rocker shafts for various auto parts and motorcycle parts; various gears, spline shafts, transmission axles, High-frequ

Troubleshooting of Medium Frequency Furnace

Troubleshooting of Medium Frequency Furnace This article introduces the faults and solutions of medium frequency furnace. 1. Fault phenomenon: large DC current, low DC voltage, and if the voltage, dull equipment sound, over-current protection. Analysis and treatment: the thyristor with one arm of the inverter bridge may be short-circuited or open-circuited, resulting in the operation of the three-arm inverter bridge. Use an oscilloscope to observe the voltage drop waveform of the thyristor on the four bridge arms of the inverter bridge. If the voltage drop waveform of the thyristor on one bridge arm is a line, the thyristor has been through; if it is a sine wave, the thyristor has not been through. Replace the through thyristor; find out the reason why the thyristor is not turned on. 2. Fault phenomenon: when the heavy load cold furnace is started, all electrical parameters and sounds are normal, but the power cannot be raised, and overcurrent protection. Analysis and

Advantages and Disadvantages of Electric Arc Furnace and Induction Furnace Steelmaking

Electric Arc Furnace VS Induction Furnace Steelmaking Comparison of advantages and disadvantages of electric arc furnace and induction  furnace steelmaking 1. The induction furnace heats up quickly and has high thermal efficiency. The heat is generated inside the charge (steel liquid), so the heating is fast. In the arc furnace, the heat of the arc after the material is cleared must be transferred to the molten steel through the slag, which is indirect heating. Thermal efficiency is poor. The furnace is in the shape of a basin, and a large part of the heat of the arc is lost through the furnace cover and the furnace wall. 2. The oxidative burning loss of elements in induction furnace steelmaking is less. Because there is no ultra-high temperature action of the arc in the induction furnace steelmaking, the burning rate of the elements in the steel is low. 3. In the induction furnace steelmaking, the composition and temperature of the molten steel are relatively uniform.