Induction Furnace Repair


Intermediate frequency furnace inductor fault repair method

Today, the editor of Luoyang Wanfeng Industrial Furnace will introduce the problem of sensor fault maintenance. The inductor in the intermediate frequency furnace is an extremely important part, so it is extremely important to master the maintenance and repair of the inductor.


Maintenance time of induction coil of intermediate frequency electric furnace

1. Once a month, check whether the coil insulation of the intermediate frequency furnace is raised or partially carbonized, and wash it with workshop air.

2. Check once a month whether there are attachments on the surface, and blow it with compressed air in the workshop.

3. Check whether the intermediate frequency furnace coil insulation board is extended in the repair room every month.

4. Check the assembly screws of the lifting coil every three months to tighten the screws.

5. Weekly visual inspection for loose helical compression springs

6. Check whether there is water leakage at the joint of the rubber tube every day.

7. Check the rubber tube for scratches once a week.

8. Remove the rubber hose, and check the corrosion resistance of the anti-rust joint at the end of the coil ("anti-corrosion pipe") after half a year. When the connector is rusted, it should be replaced in time, usually every two years.

9. Under the conditions of rated metal solution and rated power, record the temperature and minimum value of each branch of the coil with an infrared thermometer every day.

10. Compressed air is blown out of the coil every day and discharged from the surface of the dust-splashing solution. 11. The induction coil water pipe is pickled every two years.


The cause of the failure of the induction coil of the intermediate frequency electric furnace


1. This kind of failure is especially prone to occur in small intermediate frequency furnaces. Due to the small furnace, thermal stress causes deformation during operation, resulting in an inter-turn short circuit. The fault indicates that the current is large and the operating frequency is higher than normal.

2. The induction coil leaks, which can cause sparks between the coils, and the importance of repairing running welding in time.

3. The steel sticks to the induction coil of the intermediate frequency furnace, and the steel slag is hot and red, which will cause the copper tube to burn. It must be cleaned in time.


Precautions for maintenance of induction coil of intermediate frequency electric furnace


1. The operating frequency of the induction coil in the intermediate frequency furnace is relatively poor, especially the casting and smelting parts, especially dust or iron filings.

Due to the falling off of iron filings or slag on the coil of the intermediate frequency furnace or the carbonization of the surface of the insulating bakelite, a short circuit between turns is caused, which causes fire between the turns, and the copper tube of the coil breaks, resulting in failure of the intermediate frequency furnace.

Therefore, use the intermediate frequency furnace to clean the site regularly and concentrate on the coils to avoid wasting iron or iron on the coils of the intermediate frequency furnace.

2. Attention should be paid to the inlet and outlet directions of the intermediate frequency furnace coil cooling water.

The correct direction of cooling water is down, up and down to avoid fouling of the water tank. The intermediate frequency furnace should be equipped with a pressure water cooling coil, and more attention should be paid to the flow of other water to ensure the cooling effect of the intermediate frequency furnace coil.

3. Regardless of whether the intermediate frequency electric furnace is used for diathermy or smelting, attention should be paid to the use of furnace lining. If the furnace lining will damage the metal oxide on the coil, it will cause a short circuit between turns.

If the lining breaks, it will cause the furnace to penetrate (due to the thinning of the lining, the molten steel flows through the lining to the induction coil).

In this case, the high-temperature molten iron will burn out the induction coil of the intermediate-frequency electric furnace. 

Therefore, the lining material of the intermediate frequency furnace should be checked frequently to avoid damage to the lining due to thermal shock.


Hani Metallurgy is the one-stop supplier able to design, manufacture, install, and commission your melt shop and hot rolling mill plant from A to Z.


Free send inquiries to stella@hanrm.com  or inquiry99@hanmetallurgy.com if any needs.

Email: stella@hanrm.com Or stellarollingmill@gmail.com                              inquiry99@hanmetallurgy.com

Whatsapp/Wechat:+8615877652925

Website:  https://www.hanmetallurgy.com

评论

此博客中的热门博文

Application Range of Medium Frequency Induction Furnace

  Application Range of Medium Frequency Induction Furnace (1) Intermediate frequency induction furnace is used for forging and rolling 1. Wheel forgings, ring forgings, shaft forgings, cylinder forgings, gear forgings, stainless steel forgings, and large flanges. 2. Hot heading of standard parts and fasteners, such as heating for tempering, forging, and extrusion of high tools. 4. Quenching and tempering of bar materials (2) Intermediate frequency induction furnaces are used for smelting   Including the smelting of steel, gold, silver, copper, and aluminum, especially in the foundry industry (3) Intermediate frequency induction furnace is used for heat treatment 1. Heat treatment of various hardware tools and hand tools. Such as pliers, wrenches, screwdrivers, hammers, axes, etc. 2. High-frequency hardened crank pins, sprockets, camshafts, valves, various rocker arms, rocker shafts for various auto parts and motorcycle parts; various gears, spline shafts, transmission axles, High-frequ

Troubleshooting of Medium Frequency Furnace

Troubleshooting of Medium Frequency Furnace This article introduces the faults and solutions of medium frequency furnace. 1. Fault phenomenon: large DC current, low DC voltage, and if the voltage, dull equipment sound, over-current protection. Analysis and treatment: the thyristor with one arm of the inverter bridge may be short-circuited or open-circuited, resulting in the operation of the three-arm inverter bridge. Use an oscilloscope to observe the voltage drop waveform of the thyristor on the four bridge arms of the inverter bridge. If the voltage drop waveform of the thyristor on one bridge arm is a line, the thyristor has been through; if it is a sine wave, the thyristor has not been through. Replace the through thyristor; find out the reason why the thyristor is not turned on. 2. Fault phenomenon: when the heavy load cold furnace is started, all electrical parameters and sounds are normal, but the power cannot be raised, and overcurrent protection. Analysis and

Advantages and Disadvantages of Electric Arc Furnace and Induction Furnace Steelmaking

Electric Arc Furnace VS Induction Furnace Steelmaking Comparison of advantages and disadvantages of electric arc furnace and induction  furnace steelmaking 1. The induction furnace heats up quickly and has high thermal efficiency. The heat is generated inside the charge (steel liquid), so the heating is fast. In the arc furnace, the heat of the arc after the material is cleared must be transferred to the molten steel through the slag, which is indirect heating. Thermal efficiency is poor. The furnace is in the shape of a basin, and a large part of the heat of the arc is lost through the furnace cover and the furnace wall. 2. The oxidative burning loss of elements in induction furnace steelmaking is less. Because there is no ultra-high temperature action of the arc in the induction furnace steelmaking, the burning rate of the elements in the steel is low. 3. In the induction furnace steelmaking, the composition and temperature of the molten steel are relatively uniform.